Wire Rope
Steel wire rope in 6×19, 6×37, 8×19S, 18×7, 18×19 and 35W7 constructions, galvanized or bright, with fibre or steel cores — for fishing gear, elevators, hoists and prestressed stay wire. Rope is supplied on reel or cut to length, with terminations fitted on request.
Reading the code: 6×19 FC, IWR and IWS
The first number is the number of strands, the second the number of wires in each strand. So 6×19 is six strands of nineteen wires: flexible enough to run over a sheave, stiff enough to hold shape.
The letters are the core. FC is a fibre core, which keeps the rope supple and lets it bed down on a drum. IWR is an independent wire rope core, IWS an independent wire strand core. Both raise breaking strength and resistance to crushing; both make the rope stiffer. If a quote does not say which core, the price is not comparable.
When rotation actually matters
A single-layer 6×19 rope twists as it takes load, because the strands are laid in one direction. On a single-fall lift with a free hook that twist shows up as a spinning load.
Multi-strand constructions — 18×7, 18×19, 35W7 — are built with alternating lays so the torque cancels. They cost more and are stiffer, and they are the right answer for a single-fall hoist or an offshore lift where the load must not rotate. For a two-fall block, ordinary 6×19 is fine.
Which construction for which job
Pick by how the rope is used, not by the tonnage alone. A rope that runs over small sheaves needs more, smaller wires; a rope that sits in a stay needs fewer, larger ones.
| Construction | Character | Typical use |
|---|---|---|
| 6×19 FC / IWR / IWS | General purpose, good fatigue life | Hoists, winches, general rigging |
| 6×37 FC / IWR / IWS | Most flexible of the common lays | Small sheaves, running rigging |
| 8×19S DIN 3062 | Elevator rope, low stretch | Passenger and goods lifts |
| 18×7 · 18×19 · 35W7 | Rotation-resistant | Single-fall lifts, offshore, tower cranes |
| 1×7 · 1×19 PC strand | Prestressed stay wire, high tensile | Structural stay, prestressed concrete |
Questions buyers ask before ordering
What does 6×19 mean on a wire rope?+
Six strands, nineteen wires per strand. It describes the construction, not the diameter — two 6×19 ropes of the same diameter can have different breaking strengths if the core or the wire grade differs.
What is the difference between FC, IWR and IWS?+
The core. Fibre core is supple and cheaper; independent wire rope core and independent wire strand core are stronger and resist crushing better, at the cost of flexibility.
Galvanized or bright?+
Galvanized for outdoor, marine and humid service. Bright (ungalvanized) where the rope runs inside a machine, is lubricated in service, or will be coated later.
Can you cut to length and fit terminals?+
Yes — cut lengths, thimbles, clamps, swaged terminals and spliced eyes. Send the assembly drawing and the working load for a quotation.
Do you supply certificates?+
Mill certificates with heat number and breaking load come with the shipment. Third-party inspection through TÜV or SGS can be arranged.
Need wire rope to your own specification?